Ȩ£¼ Á¦Ç°¼Ò°³ £¼ HIRAYAMA£¼ HRG-112/140    
HRG-112/140 Horizontal Autoclave with Automatic Drying Function
 
Ç°       ¸í AUTOCLAVE
¸ð  µ¨  ¸í HRG - 112(»çÁø¸ðµ¨¸í)
Á¦  Á¶  ±¹ ÀÏ º»
Á¦  Á¶  »ç HIRAYAMA
Á¦Ç° »ç¾ç



- ¿ÜÇü Ä¡¼ö(W×D×H) : 691× 1048 × 1374mm
- è¹ö ³»°æ : 420 × 810mm
- ¿ë·® : 112 liters
- è¹öÀçÁú : ½ºÅ×Àη¹½º ½ºÆ¿ (SUS 304)
- ÃÖ´ë ¾Ð·Â : 0.4 MPa
- »ì±Õ ¿Âµµ : 105¡É¡­135¡É
 
Vertical Sliding Door.   Interlock System.
The vertical sliding door is employed for opening and closing of the door. (manual operation). Open-close movement is smooth, and you feel safe due to an automatic locking device. Anyone can operate the door easily, certainly and safely.   This equipment is a safety design. The door is locked by detection the pressure, temperature and water level inside the chamber. when the equipment has been interrupted, or, needless to say, when it is under sterilization operation.
Convenient Sliding Tray.   The drying function has been inproved.
The sliding tray which is convenient for taking a load in and out is equipped. Since you can easily set a load close at hand, the work can be performed safely without putting in a hand to the back of the chamber when the sterilzation has been completed. In addition, since the sliding tray can be removed, cleaing the inside of the chamber is very easy. Our purpose is the improvement of the safety and the workability.   Drying capacity has been further improved by the new drying method which employed the high capacity vacuum pump.
Moreover, an additional drying stage is also available. The additional drying stage can be set up easily with the operation panel.
Large-sized Operation Panel   The installation space can be used effectively.
The large-sized operation panel is newly employed. The proceeding atate can be checked at one glance. and the stage or the selected cycle by the load is displayed with lamps on the operation panel.   Compared with conventional horizontal door opening and closing system, the vertical sliding system can reduce the required operation space. So, even if the space is limited, it is possible to use it effectively..
   
 
 
Model HRG-112 HRG-140
   Outer dimensions 691 W × 1048 D × 1374 H mm 610 W × 1248 D × 1374 H mm
   Chamber size  420 ¥õ × 810 Dmm ( 112L)  420 ¥õ × 1010 Dmm ( 139.9L)
   Net weitht 213 Kg 229 Kg
   Power source AC   220V / 230V / 240V,   50 / 60 Hz, Single phase ( Plaease specify the voltage when ordering)
   Type of vessel Small size pressure vessel
   Chamber material Stainles steel SUS304
   Working temperature range 105 ¡É~ 135 ¡É ( Variable)
   Sterilization time 1 ~ 60 min. ( Remaining time display )
   Drying time 1 ~ 99 min. ( Remaining time display )
   Selectable cycle 4 cycles ( cloth, solid, liquid, additional dry), 3 memory patterns
   Safety valve working pressure 0.26 MPa
   Thermometer 5 ~ 137 ¡É, Resolution 0.1, Digital
   Compound gauge -0.1 ~ 0.4MPa
   Drying method By vacuum pump and heater
   Safety devices and Pressure safety valve, Leakage breakers, Over-heat prevention device
   Error Display   Error display for ; Over-heat, Over-pressure, Door trouble, Heater trouble, Water supply or drainage trouble Vacuum
  pump trouble
   Type of a power cord Solderless ring terminal (Without a plug)
¡ØSpecifications subject to change without notice due to continuous product improvement.
 

Recorder
High speed 6 dot-printing
recorder,
Measuring point : 6,
Measuring cycle : 10,
seconds, With 1set of
temperature sensor.

Stainless steel squarer
   wire basket







Stainless steel squarer
   bottomed basket







Stainless steel dressing
   drum





Floating sensor-Activated by the temperature of the objects.
Digital printer